(C102SR10) Quartz Micro Cuvette, 10 mm Path, 1.75 mL
Original price was: $72.00.$65.00Current price is: $65.00.
C102SR10 is a quartz micro cuvette with a 10 mm optical path, 1.75 mL nominal capacity and a supplied closure for covered handling. Its 5 mm sample-region width and clearly stated uncapped body size of 12.5 × 12.5 × 45 mm are useful when you need to review both beam footprint and holder clearance. Sold as 1 cuvette per price unit, with closure included.
Description
C102SR10 is a quartz micro cuvette for straight-through 10 mm path measurements in a compact 1.75 mL format. This option combines a Two-Way Light layout, a 5 mm sample-region width and a supplied closure, with one especially useful detail for installation checks: the stated 12.5 × 12.5 × 45 mm dimensions apply to the uncapped cell body.
That makes this version helpful when you need to separate holder fit from closure clearance during selection. You can check the body seating first, then allow extra space above the cell for the fitted closure because the capped height is not specified here.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 1.75 mL
- Closure Type
- Stopper
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Optical Window Dimensions | 5 mm |
| Sample Volume (Nominal) | 1.75 mL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 45 mm |
| Overall Height without Closure | 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Closure Type | Stopper |
| Closure Included | Yes |
| Fabrication Method | Standard 80 |
| Detection Channel Width | 5 mm |
Choose this option
Choose C102SR10 when your method uses a 10 mm path length and you want a compact micro cuvette with a 5 mm sample region and a clearly defined uncapped body envelope. It is a practical choice for setups where holder fit, top clearance and beam footprint all matter, not just nominal capacity.
What makes this option different
- 10 mm optical path for standard straight-through absorbance measurements.
- 1.75 mL nominal capacity in a compact micro cuvette body.
- 5 mm sample-region width for beam-footprint planning in the illuminated region.
- Uncapped body dimensions of 12.5 × 12.5 × 45 mm for clearer holder and clearance checks.
- Closure included for covered sample handling after filling.
- Standard 80 adhesive-bonded construction in a quartz body.
Using this cell
Fill the cuvette from the top and confirm that the beam passes through a fully covered liquid region before measurement. Keep the optical faces free from bubbles, droplets and residue, and use the same orientation for blank and sample runs.
The nominal 1.75 mL figure describes the cell capacity, not a minimum working volume. If your method uses lower fill levels, verify that the actual liquid height covers the beam path in your instrument.
First-use check
- Inspect the optical faces and top opening for dust, chips or residue.
- Test the uncapped body in your holder to confirm square seating and side clearance.
- Run a blank first and verify full beam coverage through a bubble-free liquid region.
- After fitting the closure, make sure there is enough vertical clearance in the instrument compartment.
Fit and optical alignment
The stated outer dimensions for this SKU are the uncapped cell dimensions: 12.5 × 12.5 × 45 mm. Use those values to check holder seating and side clearance, then allow additional space above the cell for the supplied closure because the capped envelope is not defined here.
Z Height is not specified for this option. The 5 mm sample region helps you judge beam footprint, but instruments with a fixed beam-center position should be checked against the actual sample region before routine use.
Solvents and cleaning
This cuvette uses Standard 80 adhesive-bonded quartz construction. It is commonly selected for routine room-temperature work with water-based samples and buffers.
Avoid organic sample solvents and organic cleaning agents with this construction. Do not use hydrofluoric acid on quartz, and avoid hot strong alkalis and abrasive cleaning. Clean the optical faces gently with suitable non-abrasive optical or laboratory tissue.
Included with this option
1 cuvette per listed price unit. Closure included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different path length, capacity, body geometry, window arrangement or beam-height fit, we can review a custom quartz version. Send your drawing or labelled sketch, holder or instrument details, critical dimensions and application conditions through our contact page, and quote part number C102SR10.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.