(C102SR7) Quartz Micro Cuvette, 10 mm Path, 1.75 mL
Original price was: $143.00.$129.00Current price is: $129.00.
C102SR7 is a JGS1 quartz micro cuvette for UV/Vis spectroscopy with a 10 mm optical path, 1.75 mL nominal capacity and an included closure. Its Two-Way Light layout and 5 mm stated sample-region width suit routine transmission measurements in a compact 12.5 × 12.5 mm body. Supplied as 1 cuvette.
Description
C102SR7 is a JGS1 quartz micro cuvette for UV/Vis spectroscopy with a 10 mm optical path, 1.75 mL nominal capacity and an included closure. It combines a familiar transmission path with a compact body, while the 5 mm stated sample-region width gives more beam area than the narrower variants in this family. The stated wavelength range is 200–2500 nm.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 1.75 mL
- Closure Type
- Stopper
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Optical Window Dimensions | 5 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 1.75 mL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Stopper |
| Closure Included | Yes |
| Detection Channel Width | 5 mm |
Choose this option
Choose C102SR7 when you want a 10 mm quartz micro cuvette with more nominal volume and a wider stated sample region than the smallest micro-volume versions, but still in the same 12.5 × 12.5 mm body format. It is a practical option for routine UV/Vis work where the instrument accepts this square cuvette footprint and the filled region comfortably covers your beam.
What makes this option different
- 10 mm optical path for standard transmission methods.
- 1.75 mL nominal capacity in a compact micro cuvette body.
- 5 mm stated sample-region width for a broader illuminated region than the narrowest variants.
- JGS1 quartz for UV/Vis use over the stated 200–2500 nm range, with a closure included.
Using this cell
Fill the cell so the illuminated sample region is fully covered and free of bubbles, then place the closure gently after filling. Keep the optical faces clean and use the same orientation for blank and sample runs for more consistent handling.
The 1.75 mL value is a nominal capacity, not a minimum working volume. If your method uses a low liquid level or a fixed beam position, check that the filled region matches your setup before routine measurements.
First-use check
- Inspect the optical faces, rim and chamber for dust or transit damage.
- Test fit the cell in your holder before filling with sample.
- Run a suitable blank first and confirm stable seating and clean beam passage through the filled region.
- Fit the closure gently and check that it suits your normal bench handling.
Fit and optical alignment
The stated external dimensions are 12.5 × 12.5 × 45 mm, with a 12.5 × 12.5 mm base. These values are useful for checking holder fit and vertical clearance in a square-cell slot.
Z Height is not specified for this SKU. The optical window dimension is stated as 5 mm, and the sample-region channel width is also stated as 5 mm, so these values help you review beam footprint and sample presentation if your instrument has a tight or fixed optical geometry.
Solvents and cleaning
This cuvette uses quartz with a fused integrated construction. For fabrication background across the cuvette range, see Compare fabrication options.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. For other sample liquids and cleaning agents, check compatibility with the full cell and closure assembly before use, since the exact chemical limits for this selected configuration are not established here.
Included with this option
1 cuvette per listed price unit. Closure included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review changes to dimensions, path length, sample volume, optical windows, closures and fabrication requirements for related JGS1 quartz cuvettes. If beam height, holder fit or filling geometry is critical, send your drawing or holder details with the required dimensions and application wavelength. You can contact us here and reference C102SR7.