C104CE22 is a quartz micro cuvette for fluorescence spectroscopy that combines Four-Way Light access with a 1 mm sample channel and 350 µL nominal capacity. The 10 mm optical path suits methods that need side optical access around a narrow sample region. The listed price is for 1 cuvette, and a closure is included.
Description
C104CE22 is a quartz micro cuvette for fluorescence spectroscopy with a 10 mm optical path, Four-Way Light access and a 1 mm sample channel. This combination is useful when you need optical access from the sides of the cell while keeping the sample in a narrow measurement region, with a 350 µL nominal capacity in a compact micro-cuvette body.
The uncapped body measures 12.5 × 12.5 × 45 mm, so you can check holder fit before ordering. A closure is included with this option, but the fitted height is not listed here, so any top clearance should be checked at the instrument or fixture.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 350 µL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Optical Window Dimensions | 1 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 350 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Closure Type | Lid |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
| Detection Channel Width | 1 mm |
Choose this option
Choose C104CE22 when your fluorescence method uses side optical access and you want that access in a micro cuvette with a narrow 1 mm sample channel. The 10 mm path length gives you a standard transmission path through the sample region, while the 350 µL nominal capacity keeps the cell compact for small-volume work without changing to a different body format.
What makes this option different
- Four-Way Light layout provides optical access from four sides, which is useful for fluorescence setups that use side illumination or side collection geometry.
- 1 mm sample channel creates a narrow sample region, so filling and bubble control in that area matter for stable measurements.
- 10 mm optical path combines a familiar path length with this narrow-channel micro-cell format.
- 350 µL nominal capacity supports small-volume handling, but it is still a nominal volume rather than a minimum working fill.
- Optical-contact assembly is the stated construction method for this exact SKU.
- Closure included allows covered use after filling, while final installed height still depends on the fitted closure.
Using this cell
Fill the cell so the illuminated sample region is fully covered during measurement. Because the sample channel is narrow, it helps to load the sample carefully and check that no bubbles or droplets remain in the optical region before you place the cell in the instrument.
Keep the same orientation for blank and sample runs. After filling, fit the closure carefully and handle the cell in a way that avoids wetting or marking the optical faces.
First-use check
- Inspect the cell for chips, residue or handling marks.
- Place the empty cell in the holder and confirm smooth seating.
- Fill with a suitable blank and check that the measurement region is fully covered.
- Fit the closure and verify your normal measurement orientation before running samples.
Fit and optical alignment
The listed 12.5 × 12.5 × 45 mm dimensions apply to the uncapped cell body. Use them to check holder fit and side clearance, especially if your fluorometer or accessory has a close-fitting cuvette compartment.
Z Height is not listed for this SKU, so the outer body dimensions alone should not be used to assume beam-center alignment. If your setup depends on a defined beam height, check that requirement before ordering.
Solvents and cleaning
This cuvette is described with an optical-contact assembly and the Molded 83 fabrication classification. In practical selection terms, that makes it a relevant option for methods where the assembly choice matters alongside the optical layout, especially when you are reviewing exposure to organic solvents or temperature-related process conditions for the complete wetted assembly rather than the quartz body alone.
Suitability still needs to be judged for your actual sample, cleaning routine and the complete assembly, including the supplied closure. Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning methods, and clean the optical faces gently with non-abrasive laboratory wipes or another suitable material.
Included with this option
1 cuvette per listed price unit. A closure is included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
For a different design, send a drawing or describe the change you need. Custom quartz enquiries for dimensions, optical layout or related geometry are assessed separately from this listed specification, with feasibility, quantity, price and production time confirmed for the project.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.