(C104CE23) Quartz Micro Cuvette, 10 mm Path, 700 µL
Original price was: $323.00.$291.00Current price is: $291.00.
C104CE23 is a quartz micro cuvette for fluorescence spectroscopy with a 10 mm optical path, Four-Way Light access and a 2 mm sample channel. Its 700 µL nominal capacity gives a compact sample region that suits fluorescence work where side optical access and beam placement matter. The listed price is for 1 cuvette, with a closure included.
Description
C104CE23 is a quartz micro cuvette for fluorescence spectroscopy with a 10 mm optical path, Four-Way Light access and a 700 µL nominal capacity. Its 2 mm sample channel creates a narrow sample region inside a standard 12.5 × 12.5 mm body, which helps when you want the illuminated region to stay within a more tightly defined part of the sample. The listed option includes a closure and is sold as 1 cuvette per price unit.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 700 µL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Optical Window Dimensions | 2 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 700 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Closure Type | Lid |
| Closure Included | Yes |
| Fabrication Method | Molded 83 |
| Detection Channel Width | 2 mm |
Choose this option
Choose C104CE23 when your fluorescence setup uses a 10 mm path length but you also want side optical access and a narrower sample region than a broader micro cell provides. The 700 µL nominal capacity sits within that 2 mm channel geometry, so this option is useful when filling and aligning the optical region are both part of the method, not just the total volume.
What makes this option different
- Four-Way Light layout gives optical access from four sides, which is useful for fluorescence geometries that need side access in addition to the main transmission path.
- 10 mm optical path suits methods built around this path length without moving to a larger external body format.
- 2 mm sample channel defines a narrower sample region, so filling and orientation matter more than in a wider chamber.
- 700 µL nominal capacity provides the stated cell volume for this exact geometry, but it should not be treated as a minimum working fill.
- Quartz body with optical-contact construction uses the source-stated optical-contact joining approach classified here as Molded 83, a construction style often chosen for methods that may involve organic-solvent workflows, subject to the complete wetted assembly and actual exposure conditions.
- Compact uncapped body size of 12.5 × 12.5 × 45 mm helps you check holder clearance while keeping the familiar square cuvette footprint.
- Closure included gives you the supplied covered configuration for this sale unit, but the fitted overall height is not listed here.
Using this cell
Fill the cell so the optical region is covered during measurement, and check that bubbles do not sit in the 2 mm sample channel. Because the channel is narrow, it is good practice to keep the same orientation for blank and sample measurements.
Fit the supplied closure gently after filling. The 700 µL figure is the nominal capacity of the cell body, not a working-volume instruction, so your practical fill level should be set by the measurement geometry in your instrument.
First-use check
- Inspect the optical faces, upper rim and channel opening for chips, residue or handling marks.
- Place the empty cell in the holder and confirm that it seats freely without forcing.
- Fill with a suitable blank and verify that the intended optical region is fully covered and free of bubbles.
- Repeat with the closure fitted and confirm the measurement orientation you plan to use in routine work.
Fit and optical alignment
The published outer dimensions apply to the uncapped cell body: 12.5 × 12.5 × 45 mm. Use those dimensions for holder seating and side clearance checks, especially if your fixture closely surrounds the body.
Allow extra clearance above the cell because this option includes a closure and the assembled height is not listed here. Z Height is also not listed, so if your fluorometer or holder depends on a defined beam-center height, that point should be checked before ordering rather than inferred from the body size alone.
Solvents and cleaning
This cuvette is classified as Molded 83 and the source identifies an optical-contact construction method. In practical selection terms, this construction is commonly chosen for quartz cuvettes used in organic-solvent methods, but suitability still depends on the complete wetted assembly, including the supplied closure, and on the actual solvent, concentration, temperature and contact time in your procedure.
Do not use hydrofluoric acid with quartz. Avoid hot strong alkalis and abrasive cleaning methods. Clean the optical faces with non-abrasive laboratory wipes and an appropriate cleaning liquid for your procedure.
Included with this option
1 cuvette per listed price unit. Closure included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
For a different design, discuss your requirements and quote part number C104CE23. Custom quartz projects are reviewed separately from this listed specification, including changes to dimensions, optical path, access geometry or other project-specific details.
Additional information
| Weight | 30 g |
|---|