(C104SR10) Quartz Micro Cuvette, 10 mm Path, 350 µL
Original price was: $293.00.$264.00Current price is: $264.00.
C104SR10 is a JGS1 quartz micro cuvette for fluorescence work, with a 10 mm optical path, Four-Way Light access and a narrow 1 mm sample-region channel. Its 350 µL nominal capacity and covered format suit methods that need a compact cell with direct side optical access. Supplied as 1 cuvette per price unit, with a closure included.
Description
C104SR10 is a JGS1 quartz micro cuvette for fluorescence spectroscopy, combining a 10 mm optical path with Four-Way Light access in a compact 12.5 × 12.5 mm body. Its 1 mm sample-region channel makes this option useful when your method is built around a narrow illuminated section and careful beam placement, while the 350 µL nominal capacity keeps the cell in a small-volume format. A closure is included for covered sample handling.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 350 µL
- Closure Type
- Stopper
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Optical Window Dimensions | 1 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 350 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Stopper |
| Closure Included | Yes |
| Detection Channel Width | 1 mm |
Choose this option
Choose C104SR10 when you need a covered quartz micro cuvette with side optical access and a narrow sample region rather than a broad internal chamber. The 10 mm path suits standard transmission distance requirements, while the 1 mm channel helps define a slim measurement zone inside the cell. This is a practical choice when your fluorescence setup needs a compact cuvette body but the beam still needs to pass through a specifically positioned narrow region.
What makes this option different
- 1 mm sample-region channel: the measurement zone is intentionally narrow, so filling and beam placement should be planned around that slim internal section.
- 10 mm optical path: gives a stated full-length path through the sample region in a micro-cuvette format.
- Four-Way Light configuration: adds side optical access for fluorescence measurement layouts without turning this into a claim of universal instrument fit.
- 350 µL nominal capacity: keeps the cell in a compact small-volume format while remaining a complete covered cuvette rather than an open chamber.
- Fused integrated construction: the source describes the cell as an integrated fused assembly, so the sample region and body are handled as one built cell rather than as a demountable plate-and-spacer arrangement.
- Covered format: supplied with a closure for contained sample handling after filling.
Using this cell
Fill the cuvette so the narrow 1 mm sample region is fully covered at the point where your beam passes through. Because the stated 350 µL figure is a nominal capacity, not a minimum working volume, your actual fill level should be set by the beam position and by how the cell sits in your holder.
After filling, fit the closure gently and keep the same orientation for blank and sample measurements. This helps you place the beam through the intended narrow section each time and reduces variation from rotating the cell between runs.
First-use check
Inspect the optical faces under good light, rinse with a liquid suitable for your method, and confirm that the cuvette seats squarely in the holder. Run a blank in the intended orientation and verify that the filled sample covers the beam path through the narrow measurement region without visible bubbles.
Fit and optical alignment
The external dimensions are 12.5 × 12.5 × 45 mm, which helps with holder clearance planning. The narrow 1 mm channel is an internal sample-region feature, not an instrument slit setting, so outside size alone does not establish beam alignment.
Z Height is not stated for this SKU. If your instrument uses a fixed optical axis, check the beam position against the actual seated cell before ordering or routine use.
Solvents and cleaning
The source describes this cuvette as a fused integrated construction. In practical use, that means you handle it as a complete assembled cell rather than taking apart a separate cover-plate sample cavity. For background on MQ fabrication categories, see the fabrication guide.
Chemical compatibility for the complete assembly is not established here. If your method involves aggressive reagents, long contact time or cleaning solvents, check the exact liquid and conditions before use. Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and clean the optical faces gently with non-abrasive optical tissue.
Included with this option
1 cuvette per listed price unit. Closure included.
Availability and ordering
Order this listed specification directly, or ask about current availability and dispatch. If your delivery date is important, ask before checkout; preparation or production time is separate from transit and customs clearance.
Discuss a custom version
For a different design, send a drawing or describe the change you need. Custom JGS1 quartz enquiries are assessed separately from this listed specification. Please mention C104SR10 and include your holder details, beam position, critical dimensions, wavelength range and sample conditions.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.