(C104CS63) Quartz Ultra-Micro Cuvette, 10 mm Path, 200 µL
Original price was: $156.00.$141.00Current price is: $141.00.
C104CS63 is a JGS1 quartz Ultra-Micro Cuvette with a 10 mm optical path, Four-Way Light configuration and 200 µL nominal capacity. Its open-top body allows direct filling, and the 8.5 mm Z Height helps you match the cell to holders or instruments with a lower beam centre. Supplied as 1 cuvette.
Description
C104CS63 is a JGS1 quartz Ultra-Micro Cuvette for methods that need a 10 mm optical path in a compact body. This version combines Four-Way Light access, an open top and a 200 µL nominal capacity, with an 8.5 mm Z Height for setups that use a lower beam position. Its 12.5 × 12.5 × 45 mm body gives a familiar upright format while keeping the sample region small.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 200 µL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Ultra-Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Z Height | 8.5 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 200 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Body Only |
| Body Height | 45 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Opening Configuration | Open Top |
Choose this option
Choose C104CS63 when you need a compact quartz cell that still keeps a 10 mm path and a defined bottom-to-beam-centre reference. The open top suits careful manual filling and inspection, while the Four-Way Light layout is useful when your measurement geometry needs side optical access beyond a simple front-and-back arrangement.
What makes this option different
- JGS1 quartz body for applications that call for quartz rather than glass.
- Open-top format gives direct access for pipetting and visual checking of the sample region before measurement.
- 10 mm optical path keeps this ultra-micro cell aligned with methods built around a standard 10 mm path.
- Four-Way Light configuration supports optical access from four sides for suitable beam and detection layouts.
- 200 µL nominal capacity makes it suitable for small-volume loading, without implying a minimum working fill.
- 8.5 mm Z Height is the key fit reference when your holder or instrument has limited beam-height adjustment.
- 200–2500 nm stated wavelength range is relevant when your method planning includes UV/Vis use within that stated range.
Using this cell
Fill the cell from the top and check that the illuminated sample region is fully covered at your working level. Avoid bubbles, droplets on the optical faces and dried residue near the beam path, especially when working with small fills.
Use the same orientation and seating for blank and sample measurements. The 200 µL figure is a nominal capacity, not a minimum working volume, so the practical fill level depends on your beam height, beam size and holder position.
First-use check
- Inspect the optical faces and opening for chips, dust or residue.
- Place the cell in your holder and confirm square, stable seating.
- Run a blank in the same orientation planned for samples.
- Check that the beam passes through the intended filled region without clipping.
Fit and optical alignment
The body dimensions are 12.5 × 12.5 × 45 mm. These are body dimensions rather than a capped overall envelope, so review holder seating and top clearance if you pipette in place or work close to a cover or clamp.
The Z Height is 8.5 mm from the bottom of the cell to the optical centre. Compare that bottom reference directly with your instrument beam centre rather than assuming fit from overall body height alone.
Solvents and cleaning
Quartz is often selected for UV/Vis work, and this cell is specified here with a 200–2500 nm wavelength range. For fabrication background, see MQ Cuvette Fabrication Glossary.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Clean the optical faces gently with suitable non-abrasive laboratory or optical wipes, and check compatibility if your sample or cleaning routine involves more demanding chemicals.
Included with this option
Supplied as 1 cuvette. A closure is not established for this option, so choose it as an open-top cell unless your project uses a separate closure or holder arrangement.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch and identify the dimensions and tolerances that are critical to your application. Prototype batches typically involve 2–4 cells; final feasibility, specification, price and production time are confirmed in the project quotation. Discuss your requirements and quote part number C104CS63.
Additional information
| Weight | 30 g |
|---|