(C104CR1) Quartz Fluorescence Cuvette, 10 mm Path, 3.5 mL, Pack of 2
Original price was: $189.00.$171.00Current price is: $171.00.
C104CR1 is a JGS3 quartz fluorescence cuvette with a 10 mm optical path, Four-Way Light access and 3.5 mL nominal capacity for fluorescence and infrared measurement work. Its full-size rectangular body gives optical access from multiple side directions while keeping a conventional cuvette format.
Description
C104CR1 is a JGS3 quartz fluorescence cuvette with a 10 mm optical path, Four-Way Light geometry and 3.5 mL nominal capacity. It suits fluorescence and infrared work that needs a full-size rectangular quartz cell with side optical access from more than one direction. This sale option is supplied as a pack of 2 cuvettes.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 3.5 mL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Fluorescence Cuvette |
| Measurement Mode | Infrared Spectroscopy; Fluorescence Spectroscopy |
| Pack Quantity | Pack of 2 |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 260 nm |
| Wavelength Range — Upper Limit | 3500 nm |
| Sample Volume (Nominal) | 3.5 mL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS3 |
| Closure Type | Lid |
| Closure Included | Yes |
Choose this option
Choose C104CR1 when your method uses a standard 10 mm path and benefits from optical access through four side faces rather than a single fixed viewing direction. The 3.5 mL nominal capacity fits routine liquid samples in a full-size cell, and the supplied covered configuration is useful when you want the cuvette with its included closure arrangement rather than an explicitly open-top accessory or demountable assembly.
What makes this option different
- 10 mm optical path: a familiar path length for transmission-based liquid measurements, with a full-size sample region rather than a micro-volume layout.
- Four-Way Light configuration: side optical access on four faces gives more freedom in how you orient the cell for excitation and collection geometry in supported fluorescence work.
- 3.5 mL nominal capacity: the sample chamber is sized for millilitre-scale filling rather than trace-volume loading, which can be preferable for routine handling and repeatable liquid placement in a larger cell.
- JGS3 quartz material: specified here for fluorescence and infrared spectroscopy use, with a stated 260–3500 nm range.
- Fused integrated construction: this is supplied as an assembled cuvette body, not a demountable plate-style cell that requires separate sample sandwiching before measurement.
- Accompanying lids: cover the top openings between filling and routine handling; no sealing or pressure performance is specified.
Using this cell
Handle the optical faces carefully and keep them clean and dry on the outside before measurement. For fluorescence work, keep the cuvette orientation consistent between blank and sample so the same side faces are presented to the instrument each time.
The nominal 3.5 mL capacity describes the cuvette chamber size, not a minimum working volume. If your method depends on low fill height, a fixed beam position or a specific observation geometry, check the filled sample position in your own setup before routine use.
First-use check
- Inspect the quartz body for chips, residue or visible handling marks on the optical faces.
- Place the cuvette in your holder and confirm stable seating with clear beam passage through the intended side faces.
- Run a blank in the same orientation you plan to use for samples.
Fit and optical alignment
The body dimensions are 12.5 × 12.5 × 45 mm for the uncapped cell. Use these uncapped dimensions to check holder clearance and surrounding space for the quartz body itself.
Allow additional room for the supplied closure arrangement, because the installed overall size with closure is not listed here. Four-Way Light describes the available side optical access, but it does not by itself establish compatibility with a particular holder, fluorimeter or infrared accessory. Z Height is not listed for this SKU, so beam-height alignment should be checked in the intended instrument.
Solvents and cleaning
Clean with methods suitable for quartz and for the complete wetted assembly used in your application. Do not use hydrofluoric acid on quartz, and avoid hot strong alkalis and abrasive cleaning materials on the optical faces.
Specific chemical limits and pressure limits are not listed for this SKU. If your method involves aggressive solvents, elevated temperature or long contact time, check suitability before routine use.
Included with this option
The listed price covers 2 C104CR1 quartz fluorescence cuvettes, with accompanying lids and a storage box.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for changes to dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch through the contact page and mention part number C104CR1.
Additional information
| Weight | 30 g |
|---|