(C102SR20) Quartz Micro Cuvette, 10 mm Path, 1.4 mL
Original price was: $143.00.$129.00Current price is: $129.00.
C102SR20 is a JGS1 quartz micro cuvette with a 10 mm optical path, Two-Way Light layout and 1.4 mL nominal capacity. Its covered sample chamber and 4 mm sample-region width suit users who want a compact quartz cell with simple two-window optical access and more volume than narrower micro formats. Sold as 1 cuvette per price unit.
Description
C102SR20 is a JGS1 quartz micro cuvette with a 10 mm optical path, Two-Way Light geometry and 1.4 mL nominal capacity. The covered sample chamber helps during filling and handling, while the 4 mm sample-region width is useful to consider when matching the beam to the illuminated liquid area. This option suits users who want a compact quartz cell with a simple two-window optical layout rather than multi-direction access.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 1.4 mL
- Closure Type
- Stopper
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Optical Window Dimensions | 4 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 1.4 mL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Body Height | 45 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Stopper |
| Closure Included | Yes |
| Detection Channel Width | 4 mm |
Choose this option
Choose this cell when you need a covered micro cuvette with a standard 10 mm path and a larger nominal capacity than the narrower micro variants in the same general format. The Two-Way Light layout keeps the optical direction simple, and the 4 mm sample-region width gives a practical reference when planning beam coverage through the filled sample.
What makes this option different
- 10 mm optical path: standard transmission geometry in a compact micro body.
- Two-Way Light layout: optical access through two opposed faces rather than a multi-side format.
- 1.4 mL nominal capacity: more sample volume than smaller slit micro versions.
- 4 mm sample-region width: a useful sizing point for beam coverage and fill planning.
- Covered format: closure included, with 1 cuvette sold per price unit.
Using this cell
Fill the cuvette so the beam passes fully through liquid and remove visible bubbles before measurement. Keep the optical faces clean, and use the same seating and orientation for blank and sample runs to keep the optical path consistent.
The 1.4 mL value is the nominal capacity, not a minimum working volume. If you plan to run with less sample, check in your own setup that the liquid level still covers the beam position you intend to use.
First-use check
Inspect the optical faces, rinse the cell with a suitable liquid for your method, and check that the closure seats cleanly before first use. Then run a blank to confirm clear transmission, fill coverage and the absence of visible bubbles in the illuminated region.
Fit and optical alignment
The cell body is 12.5 × 12.5 × 45 mm with a 12.5 × 12.5 mm base. These dimensions help you check holder seating and general external clearance, but they do not provide a Z Height value.
This is a Two-Way Light cuvette with optical access through two opposite faces. If your spectrometer or holder uses a fixed beam height, confirm beam alignment before ordering because Z Height is not listed for this item.
Solvents and cleaning
This quartz cuvette is described with fused integrated construction. Product-specific chemical limits for this exact sale item are not listed here, so choose sample, rinse and cleaning liquids to match your own method conditions.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the exterior optical faces gently with non-abrasive optical tissue.
Included with this option
1 cuvette per listed price unit. Closure included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz projects for changes to dimensions, optical path length, sample volume, optical windows, Z Height, closures and other fit requirements. Send a dimensioned drawing or labelled sketch together with your holder details, sample conditions, target quantity and delivery timing. Discuss your requirements and quote part number C102SR20.
Additional information
| Weight | 30 g |
|---|