(C102CR12) Quartz Micro Cuvette, 10 mm Path, 350 µL
Original price was: $72.00.$65.00Current price is: $65.00.
C102CR12 is a quartz micro cuvette for UV/Vis work with a 10 mm optical path, 350 µL nominal capacity and a 1 mm sample region in a Two-Way Light layout. Its open-top body gives direct filling access for small-volume handling. Sold as 1 cuvette, with an included closure.
Description
C102CR12 is a quartz micro cuvette for UV/Vis measurements when you need a 10 mm path length in a compact 350 µL format. The open-top body gives direct access to the sample chamber during filling, and the 1 mm sample region helps you plan beam coverage more carefully than a wider chamber. This option is sold as 1 cuvette, with an included closure.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 350 µL
- Opening Configuration
- Open Top (Cell Body)
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Sample Volume (Nominal) | 350 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 45 mm |
| Overall Height without Closure | 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Closure Type | Lid |
| Closure Included | Yes |
| Opening Configuration | Open Top (Cell Body) |
| Detection Channel Width | 1 mm |
Choose this option
Choose C102CR12 when you want a small-volume UV/Vis cell that you can fill directly from the top without threaded fittings or a demountable plate assembly. Its 10 mm optical path suits standard absorbance geometry, while the 350 µL nominal capacity keeps the sample chamber compact. The bare cell body is 12.5 × 12.5 × 45 mm, which is useful when checking holder seating and vertical clearance around the open rim.
What makes this option different
- Open-top cell body for direct top filling and straightforward access to the sample chamber.
- 10 mm optical path for UV/Vis measurement in a micro cuvette format.
- 350 µL nominal capacity for methods that use a compact sample chamber.
- Two-Way Light layout for transmission measurement through the stated optical path.
- 1 mm sample region, which makes beam placement and full coverage of the illuminated area more important during filling.
- 12.5 × 12.5 × 45 mm uncapped body dimensions for checking holder fit and top clearance separately from the closure.
Using this cell
Fill the cell from the top and make sure the illuminated region is fully covered before measurement. Remove bubbles from the optical path and keep the same orientation for blank and sample runs so the beam passes through the same part of the cell each time.
The 350 µL figure is the nominal capacity of the cell, not a minimum working volume. After filling, place the closure carefully for measurement, but do not treat that closure as a pressure-rated seal or as a basis for transport handling.
First-use check
- Inspect the optical faces and rim for chips, dust, residue or fingerprints.
- Test fit the empty uncapped body in the holder and check top clearance for the closure.
- Run a blank and confirm that the filled sample covers the beam without trapped bubbles.
Fit and optical alignment
The listed 12.5 × 12.5 × 45 mm dimensions apply to the uncapped cell body. Use those figures to check whether the body seats correctly in your holder, then allow additional space above the rim for the closure arrangement.
Z Height is not specified for this SKU. If your instrument depends on a defined beam-center height, check your holder geometry and beam position before ordering rather than assuming alignment from the outer body size alone.
Solvents and cleaning
This SKU is described in the source as a powder-fused construction type. That process description is useful as a structural distinction, but it does not establish a full chemical compatibility list for this exact item.
Chemical limits are not specified here for this SKU. Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, rinse promptly after use, and wipe the exterior optical faces gently with non-abrasive optical tissue.
Included with this option
One C102CR12 quartz micro cuvette with an included closure.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for changes to dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication requirements. If you need a different fit, send a labelled drawing or sketch together with holder details, application wavelength, sample conditions and target quantity. Discuss your requirements and reference C102CR12.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.