(C102CM) Quartz Standard Cuvette, 10 mm Path, 3.5 mL
Original price was: $31.00.$28.00Current price is: $28.00.
C102CM is a JGS1 quartz standard cuvette for UV/Vis spectroscopy with a 10 mm optical path, Two-Way Light layout and 3.5 mL nominal capacity. Its open-top, flat-bottom form supports direct filling and routine transmission measurements. Supplied as 1 cuvette, with closure included.
Description
C102CM is a JGS1 quartz standard cuvette for UV/Vis spectroscopy with a 10 mm optical path and 3.5 mL nominal capacity. The open top gives direct access for pipetting, rinsing and visual checks, while the flat-bottom square body suits upright handling in bench and holder-based workflows. This sales unit is supplied as 1 cuvette, with closure included.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 3.5 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 3.5 mL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
| Opening Configuration | Open Top |
Choose this option
Choose C102CM when your method is built around a 10 mm transmission path and you want a full-size quartz cell rather than a flow assembly or a specialised micro format. The Two-Way Light layout supports routine straight-through optical measurements, and the 3.5 mL nominal capacity gives a standard sample chamber for general UV/Vis work. Its open-top format is also practical when you need simple filling and emptying between runs.
What makes this option different
- 10 mm optical path suits methods written for that standard transmission length.
- Two-Way Light configuration supports straight-through measurement across the opposing optical faces.
- Open-top access allows direct pipetting, rinsing and inspection of the sample chamber.
- 3.5 mL nominal capacity provides a full-size sample region for routine UV/Vis handling.
- JGS1 quartz body is stated for use over 200-2500 nm.
- Uncapped body size of 12.5 × 12.5 × 45 mm helps you check holder clearance separately from any added closure height.
Using this cell
Fill the cuvette from the open top and make sure the liquid level covers the beam during measurement. For consistent day-to-day use, keep the same orientation for blank and sample, avoid bubbles on the optical faces, and handle the cuvette by the non-optical sides where possible.
The 3.5 mL figure is a nominal capacity, not a minimum working volume. If your method uses reduced fills, confirm that the sample level still reaches the illuminated region in your instrument.
First-use check
- Inspect the optical faces, rim and base for chips, residue or visible transport damage.
- Place the empty cuvette in your holder to confirm stable seating and top clearance.
- Rinse with a suitable liquid for your method and run a blank at the measurement wavelength before routine use.
Fit and optical alignment
The recorded external dimensions apply to the uncapped cell body: 12.5 × 12.5 × 45 mm. Use those dimensions to check holder width, seating depth and top clearance for filling or placing the included closure.
Z Height is not established for this SKU. If your spectrophotometer, holder or accessory uses a fixed beam centre height, check that requirement directly rather than assuming alignment from the outer body dimensions alone.
Solvents and cleaning
This cuvette uses a quartz body with a supplier-described fused integrated construction. In practical use, that supports general UV/Vis laboratory handling, but the chemical limits for this exact assembly are not established here, including the included closure. If your sample or cleaning routine involves aggressive reagents or long contact times, check suitability before ordering.
For general fabrication background, see the MQ Cuvette Fabrication Glossary. Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the exterior optical faces gently with non-abrasive optical tissue.
Included with this option
One sales unit contains 1 cuvette. Closure is included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and fabrication details. Send a dimensioned drawing or labelled sketch and identify the dimensions and tolerances that are critical to your application. Prototype batches typically involve 2-4 cells; final feasibility, specifications, quantity, price and production time are confirmed in the project quotation. You can contact us here and reference C102CM.
Additional information
| Weight | 30 g |
|---|