(C102CR) Quartz Standard Cuvette, 10 mm Path, 3.5 mL
Original price was: $48.00.$44.00Current price is: $44.00.
C102CR is a JGS1 quartz standard cuvette for UV/Vis spectroscopy, with a 10 mm optical path, Two-Way Light layout and 3.5 mL nominal capacity. The listed body dimensions are 12.5 × 12.5 × 45 mm for the uncapped cell, and a closure is included. Sold as 2 cuvettes per listed price unit.
Description
C102CR is a standard rectangular quartz cuvette for UV/Vis work that uses a 10 mm optical path and a Two-Way Light layout. Its JGS1 quartz body is specified for 190–2500 nm use, and the 3.5 mL nominal capacity suits routine filling in a familiar full-size cuvette format. A closure is included, while the stated 12.5 × 12.5 × 45 mm dimensions apply to the uncapped cell body.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 3.5 mL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Standard Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 190 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 3.5 mL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Lid |
| Closure Included | Yes |
Choose this option
Choose C102CR when your method is built around a 10 mm transmission path and a standard square-body cuvette. This option gives you direct top filling, a nominal 3.5 mL sample volume and a straightforward opposite-face optical layout for ordinary UV/Vis measurements, without moving to a flow cell or a reduced-volume geometry.
What makes this option different
- 10 mm optical path for methods written around the common 1 cm measurement length.
- Two-Way Light layout for straight-through transmission through opposite optical faces.
- JGS1 quartz body specified for UV/Vis use from 190 to 2500 nm.
- Closure included, with the published 12.5 × 12.5 × 45 mm dimensions referring to the uncapped cell body.
Using this cell
Fill from the top and make sure the liquid level fully covers the beam during measurement. Before reading, remove visible bubbles and keep the same cell orientation for blank and sample if your procedure depends on consistent positioning.
Handle the cuvette by the non-optical sides where possible. This helps keep the light path faces cleaner and reduces wiping before measurement.
First-use check
Inspect the optical faces for dust, marks or edge damage before first use. Rinse with a suitable liquid for your method, then run a blank to confirm that the filled sample region covers the beam and that no bubbles remain in the light path.
Fit and optical alignment
The stated outer dimensions are useful for checking whether the bare cell body will seat correctly in your holder. Because these dimensions are for the uncapped cell, allow extra space above the holder for the included closure when your sample compartment lid, clamp or autosampler passes close to the top of the cuvette.
Z Height is not stated for this SKU. If your setup depends on a defined beam-center height, especially in a tight holder or accessory, check beam alignment in your instrument rather than relying on body size alone.
Solvents and cleaning
The exact chemical limits for this assembled option are not established here, so match your sample and cleaning routine to the full cell-and-closure assembly. If your work involves aggressive solvents, heated solutions or long soaking times, check those conditions before ordering.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the optical faces with non-abrasive optical tissue.
Included with this option
2 cuvettes per listed price unit. Closure included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for changes involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections. Send a dimensioned drawing or labelled sketch together with holder details, wavelength range and sample conditions. Discuss your requirements and quote part number C102CR.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.