(C104SR28) Quartz Micro Cuvette, 10 mm Path, 350 µL
Original price was: $293.00.$264.00Current price is: $264.00.
C104SR28 is a quartz micro cuvette for fluorescence spectroscopy with a 10 mm optical path, Four-Way Light access and a 350 µL nominal capacity. Its 1 mm sample-region width gives you a narrow measurement zone, and the stoppered opening lets you cover the sample during handling and measurement. Sold as 1 cuvette per price unit, with stopper included.
Description
C104SR28 is a quartz micro cuvette for fluorescence spectroscopy with a 10 mm optical path, Four-Way Light configuration and 350 µL nominal capacity. Its 1 mm sample-region width creates a narrow illuminated zone, and the stoppered opening is useful when you want the sample covered during filling, setup and measurement.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 350 µL
- Closure Type
- Stopper
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Optical Window Dimensions | 1 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 350 µL |
| Material | Quartz |
| Closure Type | Stopper |
| Closure Included | Yes |
| Detection Channel Width | 1 mm |
Choose this option
Choose C104SR28 when your method uses a 10 mm path but you want a micro-cuvette format with a narrower sample region than a wider fluorescence cell. The combination of four-side optical access, 350 µL nominal capacity and a stopper suits small-volume work where beam placement and covered sample handling both matter.
What makes this option different
- 10 mm optical path suits methods built around that path length.
- Four-Way Light configuration gives optical access from multiple sides for fluorescence setups with compatible beam geometry.
- 1 mm sample-region width provides a narrow sample zone, so beam placement through the intended region matters.
- 350 µL nominal capacity keeps this option in a small-volume micro-cuvette format without changing to a shorter path length.
- Stopper closure lets you cover the opening during preparation and measurement, while still using a direct-fill cuvette body.
- Quartz body supports the stated 200–2500 nm wavelength range for this listing.
Using this cell
Fill the cuvette so the measurement region is fully covered at the beam position, then keep the same orientation for blank and sample. With the narrow 1 mm sample region, bubbles, droplets and residue can interfere more easily if they sit in the light path.
Seat the stopper gently on a clean opening after filling when you want the sample covered. This closure is for covering the cuvette during use; this page does not establish pressure-rated, leak-tight or transport-inverted use.
First-use check
- Inspect the optical faces, opening and stopper seating area for chips, dust or residue.
- Rinse with a method-suitable liquid before first measurement.
- Test the cuvette in your holder and verify beam alignment with a blank.
- Insert the stopper gently and check that it seats cleanly before running samples.
Fit and optical alignment
The 10 mm path length and 1 mm sample-region width should match the beam geometry used by your fluorescence setup. Four-Way Light describes the available optical access pattern, but it does not by itself establish compatibility with every fluorescence holder or instrument layout.
Z Height is not established for this SKU. If your holder or instrument has a fixed beam center, confirm the required beam height and seating geometry before ordering.
The 350 µL figure is a nominal capacity, not a minimum working volume. Set the actual fill level so the beam passes through liquid cleanly and without bubbles.
Solvents and cleaning
This cuvette uses a fused integrated construction as described by the source. For selection purposes, that construction style is commonly chosen for quartz cells used in solvent-based methods, but the exact chemical limits of this assembled SKU are not established on this listing.
Review your sample and cleaning liquids against the full cell assembly before routine use. See Compare fabrication options for general construction guidance. Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the exterior optical faces with non-abrasive optical tissue.
Included with this option
1 cuvette per listed price unit. Stopper included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving optical path length, sample volume, optical windows, closures, beam-height constraints and other geometry details. Send a drawing or labelled sketch together with your holder or instrument information, sample conditions and target quantity. Discuss your requirements and quote part number C104SR28.