(C022CR3) Quartz Large-Window Cuvette, 2 mm Path, 500 µL
Original price was: $80.00.$72.00Current price is: $72.00.
C022CR3 is a JGS1 quartz large-window cuvette for UV/Vis spectroscopy with a 2 mm optical path, Two-Way Light layout and 500 µL nominal capacity. Its open-top body and 8 × 2 × 41 mm sample region make it easy to fill directly while keeping a compact 12.5 × 12.5 mm footprint. Sold per 1 cuvette.
Description
C022CR3 is a JGS1 quartz large-window cuvette for UV/Vis work, combining a 2 mm optical path with a 500 µL nominal capacity in a compact open-top body. The narrow 8 × 2 × 41 mm internal sample region gives direct pipette access from above while keeping the outside of the cell at 12.5 × 12.5 × 45 mm for holder planning.
This option suits methods that need a short transmission path and a straightforward top-filled cell rather than a closed format. It is also useful when the sample chamber shape and body size both matter for loading, rinsing and mechanical clearance around the holder.
- Path Length
- 2 mm
- Sample Volume (Nominal)
- 500 µL
- Opening Configuration
- Open Top (Cell Body)
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Large-Window Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 2 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 500 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Uncapped Cell Dimensions | 12.5 × 12.5 × 45 mm |
| Overall Height without Closure | 45 mm |
| External Dimensions Scope | Uncapped Cell |
| Body Height | 45 mm |
| Internal Dimensions | 8 × 2 × 41 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Opening Configuration | Open Top (Cell Body) |
Choose this option
Choose C022CR3 when your method uses a 2 mm path and you want direct access to a long, narrow sample chamber from the top. The open body is practical for pipetting, removing liquid and rinsing between measurements, while the 500 µL nominal capacity keeps the cell in a compact bench and holder format rather than a larger body built around the same access style.
What makes this option different
- Open-top access lets you load, empty and rinse the chamber directly from above without working through a cap or plate.
- 2 mm optical path gives the defined transmission distance for methods set up around this shorter path length.
- 8 × 2 × 41 mm internal sample region forms a long, narrow liquid column, which is useful when you want clear top access into a slim chamber.
- 500 µL nominal capacity pairs with that chamber geometry for small-volume UV/Vis work without changing to a very small external body.
- 12.5 × 12.5 × 45 mm uncapped body makes holder and nearby hardware clearance easier to check before ordering.
- Powder-fused construction identifies this exact supplier build style for the cell body, so it should be selected and cleaned as an assembled quartz cuvette rather than treated as a removable-plate or one-piece machined accessory format.
- Two-Way Light layout supports transmission through two opposed optical faces for standard absorbance-style beam travel.
Using this cell
Fill the cell from the open top and keep the liquid level high enough to cover the beam position used by your instrument. Because the chamber is narrow, add liquid steadily and check for trapped bubbles before taking a reading.
The 41 mm internal height gives a long vertical sample region for top loading, so a pipette tip can be introduced from above without needing a side connection or removable plate. Keep the orientation consistent between blank and sample measurements, and handle the cell by non-optical surfaces.
First-use check
Inspect the optical faces and the inside of the chamber before first use. After rinsing with a suitable solvent for your method, place the cell in the holder, run a blank and confirm clean windows, stable seating and full beam coverage through the filled sample region.
Fit and optical alignment
This is a Two-Way Light cuvette for beam transmission across the 2 mm path. The uncapped body measures 12.5 × 12.5 × 45 mm externally, with an internal sample region of 8 × 2 × 41 mm, which are the practical dimensions to compare with your holder opening, side clearance and any nearby clamp or cover parts.
Z Height is not specified for this SKU. If your instrument depends on a defined beam-center height, check that requirement separately rather than using the 45 mm body height as a substitute.
Solvents and cleaning
This cuvette uses JGS1 quartz for UV/Vis work over the stated 200–2500 nm range. The exact chemical limits for this assembled SKU are not specified here, so aggressive reagents, long contact times and demanding cleaning routines should be checked for suitability before routine use.
The supplier identifies this construction as powder-fused. For general fabrication guidance, see Compare fabrication options. Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the optical faces gently with non-abrasive optical tissue.
Included with this option
1 cuvette per listed price unit. If you need a supplied closure or other accessory, contact us before ordering.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz versions for changes such as dimensions, optical path length, sample volume, openings and holder-related fit requirements. Send a dimensioned drawing or labelled sketch with your instrument or fixture details, sample conditions and target quantity. Discuss your requirements and reference C022CR3.