(C024CR2) Quartz Rectangular Sample Cell, 2 mm Path, 700 µL
Original price was: $75.00.$68.00Current price is: $68.00.
C024CR2 is a JGS3 quartz rectangular sample cell for infrared spectroscopy and visible absorbance measurements. It combines a 2 mm optical path, Two-Way Light transmission, a 700 µL nominal capacity and an included closure in a slim 12.5 × 4.5 × 45 mm body.
Description
C024CR2 is a JGS3 quartz rectangular sample cell for infrared spectroscopy and visible absorbance work. It combines a 2 mm optical path with Two-Way Light transmission and a 700 µL nominal capacity in a slim 12.5 × 4.5 × 45 mm rectangular body. This makes it a practical choice when your method is built around a short rectangular path and a relatively compact sample chamber.
- Path Length
- 2 mm
- Sample Volume (Nominal)
- 700 µL
- Closure Type
- Lid
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Rectangular Sample Cell |
| Measurement Mode | Infrared Spectroscopy; Visible Absorbance Spectroscopy |
| Path Length | 2 mm |
| Light Transmission Configuration | Two-Way Light |
| Wavelength Range — Lower Limit | 260 nm |
| Wavelength Range — Upper Limit | 3500 nm |
| Sample Volume (Nominal) | 700 µL |
| External Dimensions | 12.5 × 4.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 4.5 × 45 mm |
| External Dimensions Scope | Body Only |
| Material | Quartz |
| Material Grade | JGS3 |
| Closure Type | Lid |
| Closure Included | Yes |
Choose this option
Choose C024CR2 when your method requires a 2 mm transmission path in a rectangular quartz cell rather than a longer-path body style. The JGS3 quartz material is specified for use from 260 to 3500 nm, so it suits infrared measurements while also covering visible absorbance work. The 700 µL nominal capacity provides a smaller nominal fill volume than larger rectangular cells, while keeping the standard top-loading handling style familiar for routine use.
What makes this option different
- 2 mm optical path: match the measurement method to this transmission distance and align the beam through the sample region.
- Two-Way Light: align the opposing optical faces with the transmission beam and use the same orientation for blank and sample readings.
- 700 µL nominal capacity: plan the working fill and beam footprint together so liquid covers the illuminated region; nominal capacity is not a minimum working fill.
- Accompanying closure: cover the opening after preparation and allow room to remove it; no pressure or leak-tight rating is specified.
Using this cell
Use the 2 mm path length in your method setup and fill enough sample to cover the beam area before measurement. Check for visible bubbles, and keep the same cell orientation between blank and sample so you compare like with like.
Handle the cell by the non-optical surfaces as much as possible. Keeping the transmission faces clean helps avoid fingerprints, droplets and dried residue in the optical path.
First-use check
Inspect the optical faces under good light when the cell arrives. Rinse with a suitable liquid for your method, run a blank, and confirm that the filled sample region covers the beam path cleanly without visible residue or bubbles.
Fit and optical alignment
The stated 12.5 × 4.5 × 45 mm dimensions refer to the body only. If your holder or instrument compartment is closely fitted, check seating width, depth and top clearance before ordering, because the stated size does not define the closure height above the body.
Z Height is not specified for this item. If your instrument depends on a defined beam-center height, that point should be checked before purchase.
Solvents and cleaning
This quartz cell is intended for infrared and visible transmission use, but the chemical limits for this exact SKU are not stated here. If your sample matrix or cleaning procedure involves aggressive chemicals, heated cleaning or long contact time, review suitability before routine use.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning, and wipe the optical faces gently with non-abrasive optical tissue. For general background on MQ cuvette construction options, see fabrication method of cuvettes.
Included with this option
This configuration includes an accompanying closure. Confirm the cell quantity and any separately specified accessories covered by your order.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different path length, body size, sample volume, optical window arrangement, Z Height or closure style, we can review a custom JGS1 quartz version. Please send your drawing or labelled sketch, holder or instrument details, critical dimensions and tolerances, sample conditions and target quantity through our contact page, and quote part number C024CR2.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.