(C033CS) Quartz Ultra-Micro Cuvette, 3 mm / 3 mm (dual path) Path, 45 µL
Original price was: $237.00.$214.00Current price is: $214.00.
C033CS is a JGS1 quartz ultra-micro cuvette for fluorescence spectroscopy with a 3 mm / 3 mm optical path, Three-Way Light geometry and 45 µL nominal capacity. Its open-top format gives direct access to the sample, and the 8.5 mm Z Height helps you review beam position in compatible setups. Sold as 1 cuvette per listed unit.
Description
C033CS is a JGS1 quartz ultra-micro cuvette for fluorescence spectroscopy with a compact 3 mm / 3 mm optical path, Three-Way Light access and 45 µL nominal capacity. The 8.5 mm Z Height and 3 × 5 mm window size make it useful when the sample region is small and beam placement needs to be checked carefully.
The open-top format keeps loading simple and gives direct visual access to the sample. That is helpful when you want to inspect the filled region, avoid bubbles and keep the optical area consistent between blank and sample measurements.
- Path Length
- 3 mm / 3 mm (dual path)
- Sample Volume (Nominal)
- 45 µL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Ultra-Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Path Length | 3 mm / 3 mm (dual path) |
| Light Transmission Configuration | Three-Way Light |
| Z Height | 8.5 mm |
| Optical Window Dimensions | 3 × 5 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 45 µL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Cell Body Dimensions | 12.5 × 12.5 × 45 mm |
| External Dimensions Scope | Body Only |
| Material | Quartz |
| Material Grade | JGS1 |
| Fabrication Method | Standard 80 |
| Opening Configuration | Open Top |
Choose this option
Choose C033CS when your method uses a short 3 mm optical path and a compact measurement region rather than a longer standard path cell. The practical selection points are the 8.5 mm beam height, 3 × 5 mm window size and Three-Way Light access, all of which affect how the cell sits in your holder and how the illuminated region meets the sample.
What makes this option different
- 3 mm / 3 mm optical path for methods built around a short, compact optical geometry.
- Three-Way Light configuration for measurement layouts that use more than one optical direction around the sample.
- 45 µL nominal capacity for a small sample chamber in a complete cuvette body.
- 8.5 mm Z Height for checking beam-center alignment from the cell bottom.
- 3 × 5 mm window size for setups where the illuminated area must stay within a compact optical opening.
- Open-top body for direct pipette filling and visual inspection before measurement.
- Standard 80 adhesive-bonded construction for routine room-temperature water-based work rather than solvent-heavy use.
Using this cell
Fill the cell from the open top and make sure the sample fully covers the beam path during measurement. The 45 µL value is the nominal capacity of the cell; it is not a minimum working volume.
For fluorescence work, keep the same seating direction and fill approach for blank and sample so the illuminated region stays consistent. Remove bubbles, droplets and dried residue from the optical area before measurement.
First-use check
- Inspect the optical faces for shipping residue or handling marks.
- Place the empty cell in your holder and verify seating and beam-height alignment.
- Run a blank and confirm that the filled sample region covers the beam without bubbles.
Fit and optical alignment
The body dimensions are 12.5 × 12.5 × 45 mm, body only. Check holder seating and clearance around the cell body, and compare the 8.5 mm Z Height with your instrument beam center before ordering.
The 3 × 5 mm window size and 3 mm optical path define a compact measurement region. Three-Way Light indicates the optical access category for this cell, but it does not by itself establish compatibility with a particular fluorimeter, holder or beam footprint.
Solvents and cleaning
Standard 80 is an adhesive-bonded quartz construction. It is generally chosen for routine room-temperature water-based samples and buffers.
Avoid organic samples and organic cleaning solvents with this adhesive-bonded cell. If your method uses organic solvents, mixed solvent systems or aggressive cleaning chemistry, check the full wetted assembly for suitability before use.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. Clean the optical faces gently with non-abrasive lab tissue or other suitable non-scratching materials.
Included with this option
1 cuvette per listed price unit. If you need a supplied closure or other accessory, contact us before ordering.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for changes involving dimensions, optical path length, sample volume, optical windows, Z Height, closures or fabrication requirements. Send a dimensioned drawing or labelled sketch together with your holder or instrument details, sample conditions and quantity. Discuss your requirements and quote part number C033CS.
Additional information
| Weight | 30 g |
|---|