(MQQFL034) JGS1 Quartz Screw-Top Cuvette, 0.3 mm Path, 105 µL, Four-Way Light
$768.00
JGS1 quartz screw-top cuvette with a 0.3 mm optical path, 105 µL nominal capacity and Four-Way Light access for UV/Vis and fluorescence work. The screw-top opening and M10 threaded neck help you plan top clearance and neck fit alongside the optical geometry. Sold per piece. Molded 83.
Description
MQQFL034 is a JGS1 quartz screw-top cuvette for UV/Vis and fluorescence methods that need a very short 0.3 mm optical path in an upright cell format. Its 105 µL nominal capacity, Four-Way Light layout and threaded top make it useful when you need short-path measurement together with covered top access and multi-side optical access. This sales option is priced per piece.
- Path Length
- 0.3 mm
- Sample Volume (Nominal)
- 105 µL
- Opening Configuration
- Screw-Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Screw-Top Cuvette |
| Measurement Mode | UV/Vis Spectroscopy; Fluorescence Spectroscopy |
| Path Length | 0.3 mm |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 105 µL |
| External Dimensions | 12.5 × 2.7 × 35 mm |
| Body Height | 35 mm |
| Overall Height with Closure | 58 mm |
| Base Dimensions | 12.5 × 2.7 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Screw Cap |
| Port Thread | M10 |
| Fabrication Method | Molded 83 |
| Opening Configuration | Screw-Top |
| Pack Quantity | 1 Piece |
Choose this option
Choose MQQFL034 when the method itself drives the selection: a 0.3 mm path, a small nominal sample volume and optical access from more than one side. The screw-top format is useful when you need a threaded opening rather than an open-top chamber, and the M10 neck should be checked as part of the space available above the cell and around the holder.
What makes this option different
- 0.3 mm optical path suits short-path measurements in a standard upright cell style rather than a flow-cell layout.
- 105 µL nominal capacity supports small-volume handling, with filling checked so the illuminated region is fully covered.
- Four-Way Light geometry provides optical access on multiple faces for methods that use this beam arrangement.
- Screw-top opening gives a threaded top-entry format instead of an open chamber.
- M10 threaded neck is a practical fit point to check for closure choice and neck clearance in your setup.
- Molded 83 fabrication is commonly selected for methods involving organic solvents or heated conditions, subject to the full liquid and cleaning conditions used.
Using this cell
Fill the cell carefully so the sample fully occupies the short optical gap before measurement. With a path length this short, bubbles or partial filling can interrupt the beam more easily than in a larger chamber, so it helps to inspect the sample region after filling.
For fluorescence work, keep the cell orientation consistent between blank and sample and make sure your instrument geometry uses the available optical faces appropriately. The 105 µL value is a nominal capacity, not a minimum working volume, so practical fill level should be checked in your own setup.
First-use check
- Inspect the optical faces, chamber and threaded neck for chips, residue or handling marks.
- Seat the cell in the holder and verify beam coverage with a blank.
- After filling, confirm that the illuminated region is fully covered and free from bubbles.
Fit and optical alignment
View the English selection reference. Also available in the product gallery.
The bare optical body measures 12.5 × 2.7 × 35 mm, and the overall height with cap is 58 mm. Check both the narrow body section and the extra top clearance needed for the threaded neck and closure handling.
Z Height is not established for this SKU, so fixed-beam holders should be checked against your actual beam position before ordering. The M10 thread identifies the neck interface only; it should not be treated as a pressure-rated connection.

Solvents and cleaning
Molded 83 is commonly chosen for organic-solvent methods and for some heated applications. Suitability still depends on the complete assembly and on the actual liquid, concentration, temperature and contact time used in your method.
Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaning materials. If your method involves aggressive liquids, elevated temperature or prolonged soaking, check the full conditions before use.
Included with this option
1 cuvette. The listed price is for one piece. The cell uses a screw-top opening with an M10 threaded neck, but the supplied closure arrangement for this sales option should be checked if that detail affects your order.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch and identify the dimensions and tolerances that are critical to your application.
Prototype batches typically involve 2–4 cells; the final quantity, feasibility, specifications, price and production time are confirmed in the project quotation. Modified designs and prototype batches are quoted separately from the listed SKU. Send a product-selection enquiry with SKU MQQFL034, your holder details, sample conditions and quantity.
Design notes for this configuration: 0.3 mm Screw-Top Quartz Cell: A Short Path Below a Wide Neck (MQQFL034)
Additional information
| Weight | 100 g |
|---|
You must be logged in to post a review.















Reviews
There are no reviews yet.