Site Navigation

(MQQFC026) Quartz Rectangular Sample Cell, 3 mm Path, 756 µL, Open at Both Ends

Weight50 g
SKU: MQQFC026

$275.00

In Stock

MQQFC026 is a JGS1 quartz rectangular sample cell with a 3 mm optical path, Two-Way Light layout and 756 µL nominal capacity. Its compact open-at-both-ends body suits closely fitted holders where sealing and sample handling are built around the cell. Sold as 1 piece.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQFC026 combines a 3 mm optical path with a compact JGS1 quartz body and a 756 µL nominal chamber. The open-at-both-ends format is useful when you need a small rectangular sample region but want to provide the sealing, retention or liquid-handling method through your own fixture. This item is the cell body itself rather than a ready-connected assembly.

Path Length
3 mm
Sample Volume (Nominal)
756 µL
Opening Configuration
Open at Both Ends

Selection Specifications

Product KindSpecialized Cell
Cell TypeRectangular Sample Cell
Measurement ModeTransmission Spectroscopy
Path Length3 mm
Light Transmission ConfigurationTwo-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)756 µL
External Dimensions8 × 5 × 42 mm
Body Height42 mm
Base Dimensions8 × 5 mm
Internal Dimensions6 × 3 × 42 mm
MaterialQuartz
Material GradeJGS1
Fabrication MethodMolded 83
Opening ConfigurationOpen at Both Ends
Pack Quantity1 Piece

Choose this option

Choose MQQFC026 when your method needs a 3 mm transmission path in a narrow rectangular format and space around the holder is limited. The slim outer envelope can help in compact fixtures, while the through-open chamber leaves the end treatment to your own mounting and sealing design.

View the English selection reference.

What makes this option different

  • 3 mm optical path: for methods that require this defined transmission distance.
  • Compact 8 × 5 × 42 mm exterior: useful where holder clearance is tight and body size matters.
  • Open at both ends: intended for a separate sealing or mounting arrangement rather than direct tubing connection out of the box.
  • 756 µL nominal capacity: gives a small chamber volume within a 42 mm internal length.

Structure and dimensions

Product dimensions for checking holder clearance and sample access.
Product dimensions for checking holder clearance and sample access.Open image ↗

Using this cell

Install the cell so the beam crosses the 3 mm path in the intended orientation. Keep the same orientation during blank and sample measurements, especially if the holder contacts specific faces of the body.

Before routine use, establish how the open ends will be retained and sealed in your setup and confirm that filling and draining do not trap bubbles. The stated 756 µL is nominal chamber volume, not minimum working volume.

First-use check

  1. Inspect the optical faces, corners and end openings before mounting.
  2. Check holder fit and sample retention with a blank solution first.
  3. Verify that the final setup clears bubbles and exterior droplets before measurement.

Fit and optical alignment

Use the 8 × 5 × 42 mm outside dimensions to check the holder opening and support surfaces. The 6 × 3 × 42 mm inner dimensions describe the sample chamber and should not be used as the holder clearance size.

Z Height is not listed for this item, so instrument fit should not be assumed from the body size alone. If beam position is critical, match it through the holder design or send the drawing and required beam location for review.

English selection reference
Selection reference ↗

Solvents and cleaning

Molded 83 is an MQ fabrication option often chosen for methods involving organic solvents or elevated-temperature use. Consider suitability for the complete assembly, including any sealing or support materials added around this open-ended body. For aggressive chemicals, heated operation or long contact times, send the liquid, concentration, temperature and contact time for review.

Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaners. Clean the optical faces gently with non-abrasive optical tissue.

Included with this option

1 rectangular sample cell, SKU MQQFC026. The listed price is for one piece.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz projects for changes to path length, body size, sample volume, optical windows, Z Height, interfaces, fabrication and tolerances. Send a drawing or labelled sketch with the critical dimensions, holder details and sample conditions.

Send a product-selection enquiry with SKU MQQFC026 if you need a different envelope, a defined end interface or a complete assembled cell.

Additional information

Weight50 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFC026) Quartz Rectangular Sample Cell, 3 mm Path, 756 µL, Open at Both Ends”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare