Site Navigation

(MQQFC028) Quartz Rectangular Sample Cell, 4 mm Path, 2.5 mL, Open at Both Ends

Weight50 g
SKU: MQQFC028

$275.00

In Stock

MQQFC028 is a JGS1 quartz rectangular sample cell with a 4 mm optical path, Two-Way Light layout and 2.5 mL nominal capacity. Its broader open-at-both-ends chamber suits holders that need a larger rectangular sample region while keeping sealing and support external to the cell. Sold as 1 piece.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQFC028 is an open-ended JGS1 quartz rectangular sample cell with a 4 mm optical path and a 2.5 mL nominal chamber. Its wider rectangular format provides more sample space than smaller micro-format bodies while keeping a straightforward Two-Way Light transmission layout. This option is supplied as the cell body for use in a separately designed holder or sealing arrangement.

Path Length
4 mm
Sample Volume (Nominal)
2.5 mL
Opening Configuration
Open at Both Ends

Selection Specifications

Product KindSpecialized Cell
Cell TypeRectangular Sample Cell
Measurement ModeTransmission Spectroscopy
Path Length4 mm
Light Transmission ConfigurationTwo-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)2.5 mL
External Dimensions20 × 8 × 40 mm
Body Height40 mm
Base Dimensions20 × 8 mm
Internal Dimensions16 × 4 × 40 mm
MaterialQuartz
Material GradeJGS1
Fabrication MethodMolded 83
Opening ConfigurationOpen at Both Ends
Pack Quantity1 Piece

Choose this option

Choose MQQFC028 when your method needs a 4 mm path together with a broader rectangular chamber for sample handling or fixture layout. The open-at-both-ends construction is useful when your instrument or process requires its own support, seals or end treatment rather than a preassembled connected cell.

View the English selection reference.

What makes this option different

  • 4 mm optical path: intended for methods that require this transmission distance.
  • 2.5 mL nominal capacity: provides a larger chamber than more compact rectangular bodies of the same general type.
  • 16 × 4 × 40 mm internal chamber: gives a broad rectangular sample region within a 40 mm body length.
  • Open at both ends: designed for custom mounting or sealing rather than a ready-connected assembly.

Structure and dimensions

Product dimensions for checking holder clearance and sample access.
Product dimensions for checking holder clearance and sample access.Open image ↗

Using this cell

Install the cell so the beam crosses the 4 mm path in the intended orientation and keep that orientation consistent for blank and sample measurements. Before routine use, define how the open ends will be sealed or supported and how filling and draining will be handled without trapping air.

The stated 2.5 mL is nominal chamber capacity. It does not define a minimum working volume, and the retained liquid in the full setup can change once end seals or external connections are added.

First-use check

  1. Inspect the optical faces, end edges and chamber openings before installation.
  2. Confirm holder fit and sealing approach with a blank before introducing sample.
  3. Check for stable alignment, retained sample and removal of bubbles or exterior droplets before measurement.

Fit and optical alignment

Use the 20 × 8 × 40 mm outside dimensions to check mechanical fit in the holder. The 16 × 4 × 40 mm inner dimensions describe the sample chamber and should not be used as the holder opening size.

Z Height is not listed for this cell. If your instrument or fixture depends on a specific beam height, set that through the holder design or send the drawing for review rather than assuming compatibility from the body dimensions alone.

English selection reference
Selection reference ↗

Solvents and cleaning

Molded 83 is an MQ fabrication option often chosen for methods involving organic solvents or elevated-temperature use. Consider chemical and cleaning suitability for the complete assembly, including any seals or supporting materials added around this open-ended body. For aggressive liquids, heated operation or extended contact time, send the liquid, concentration, temperature and contact time for review.

Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaners. Clean the optical faces gently with non-abrasive optical tissue.

Included with this option

1 rectangular sample cell, SKU MQQFC028. The listed price is for one piece.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz projects for changes to path length, chamber size, outside dimensions, optical windows, Z Height, interfaces, fabrication and tolerances. Send a drawing or labelled sketch with the critical dimensions, holder details and sample conditions.

Send a product-selection enquiry with SKU MQQFC028 if you need a different chamber size, a defined interface or a complete assembled version.

Additional information

Weight50 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFC028) Quartz Rectangular Sample Cell, 4 mm Path, 2.5 mL, Open at Both Ends”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare