Site Navigation

(MQQFC025) Quartz Rectangular Sample Cell, 2.5 mm Path, 2 mL, Open at Both Ends

Weight50 g
SKU: MQQFC025

$179.00

In Stock

MQQFC025 is a JGS1 quartz rectangular sample cell with a 2.5 mm optical path, Two-Way Light layout and 2 mL nominal capacity. Its open-at-both-ends body is intended for users who will build the sealing, support or liquid-handling arrangement around the cell. Sold as 1 piece.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQFC025 is a JGS1 quartz rectangular sample cell for setups that need a 2.5 mm optical path in a long open chamber. Its 2 mL nominal capacity and open-at-both-ends format make it useful when the cell body is only one part of the assembly and the holder, seals or fluid handling are provided separately. This is a body for integration, not a finished connected flow cell.

Path Length
2.5 mm
Sample Volume (Nominal)
2 mL
Opening Configuration
Open at Both Ends

Selection Specifications

Product KindSpecialized Cell
Cell TypeRectangular Sample Cell
Measurement ModeTransmission Spectroscopy
Path Length2.5 mm
Light Transmission ConfigurationTwo-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)2 mL
External Dimensions25 × 10.5 × 50 mm
Body Height50 mm
Base Dimensions25 × 10.5 mm
Internal Dimensions19 × 2.5 × 50 mm
MaterialQuartz
Material GradeJGS1
Fabrication MethodStandard 80
Opening ConfigurationOpen at Both Ends
Pack Quantity1 Piece

Choose this option

Choose MQQFC025 when you need a rectangular quartz cell with a defined 2.5 mm transmission path and a full-length open chamber that can be built into your own fixture. The long internal format is useful when your setup depends on custom end support, custom sealing or a specific sample-handling arrangement outside the cell itself.

View the English selection reference.

What makes this option different

  • 2.5 mm optical path: suited to methods that require this transmission distance across the sample.
  • Open at both ends: the cell can be built into a separate holder or sealing arrangement instead of arriving as a ready-connected assembly.
  • Long internal chamber: the 19 × 2.5 × 50 mm inner dimensions give a full 50 mm sample region through the body.
  • 2 mL nominal capacity: useful for planning chamber fill, while the retained amount in your final setup depends on how the ends are sealed and supported.

Structure and dimensions

Product dimensions for checking holder clearance and sample access.
Product dimensions for checking holder clearance and sample access.Open image ↗

Using this cell

Install the cell so the measuring beam crosses the 2.5 mm path in the intended direction. Keep that orientation consistent for blank and sample measurements, especially if your holder has a fixed support geometry.

Because both ends are open, define the filling, sealing and draining method in the final fixture before routine use. Treat the stated 2 mL as nominal chamber capacity rather than minimum working volume.

First-use check

  1. Inspect the optical faces and end openings for chips, residue or handling marks.
  2. Test the fit in the holder before introducing sample.
  3. Run a blank in the final orientation and check that bubbles and exterior droplets are cleared before measurement.

Fit and optical alignment

Use the 25 × 10.5 × 50 mm outer size to check holder clearance, support width and end access. The 19 × 2.5 × 50 mm inner dimensions describe the sample chamber and should not be used as the holder opening size.

Z Height is not listed for this cell, so beam-height matching should be set by your fixture design rather than assumed from the outside dimensions alone. Clamp the body evenly and avoid point loading on optical faces or end edges.

English selection reference
Selection reference ↗

Solvents and cleaning

Standard 80 is an adhesive-bonded quartz construction typically chosen for routine room-temperature aqueous samples and buffers. Avoid organic samples and organic cleaning solvents with this bonded assembly. If your method involves organic solvents or heated processing, ask about a more suitable Sintered or Molded alternative before ordering.

Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaning methods. Clean the optical faces gently with non-abrasive optical tissue and a mild cleaner suitable for the validated assembly use.

Included with this option

1 rectangular sample cell, SKU MQQFC025. The listed price is for one piece.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz projects for changes to dimensions, optical path length, sample volume, optical windows, Z Height, interfaces, fabrication and tolerances. Send a drawing or labelled sketch with the critical dimensions, holder details, sample conditions and target quantity.

Send a product-selection enquiry with SKU MQQFC025 if you need a different body size, a defined interface or a complete assembled solution.

Additional information

Weight50 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFC025) Quartz Rectangular Sample Cell, 2.5 mm Path, 2 mL, Open at Both Ends”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare