(MQQFC021) Quartz Rectangular Sample Cell, 20/10 mm Dual Path, 10 mL, Open at Both Ends
Description
MQQFC021 is a JGS1 quartz rectangular sample cell for UV/Vis work from 200 to 2500 nm when your setup needs two defined optical directions in one body. It combines a 20 mm primary path, a 10 mm secondary path and a 10 mL nominal chamber, so you can work with one sample region while selecting the measurement direction that fits your method.
The Four-Way Light layout adds optical access on two axis pairs, and the body remains open at both ends for integration into your own holder or end-sealing arrangement. This is useful when the optical geometry and the mechanical fixture need to be planned together.
- Path Length
- 20 mm / 10 mm (dual path)
- Sample Volume (Nominal)
- 10 mL
- Opening Configuration
- Open at Both Ends
Selection Specifications
| Product Kind | Specialized Cell |
|---|---|
| Cell Type | Rectangular Sample Cell |
| Measurement Mode | Transmission Spectroscopy |
| Path Length | 20 mm / 10 mm (dual path) |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 10 mL |
| External Dimensions | 26 × 16 × 50 mm |
| Uncapped Cell Dimensions | 26 × 16 × 50 mm |
| External Dimensions Scope | Uncapped Cell |
| Body Height | 50 mm |
| Base Dimensions | 26 × 16 mm |
| Internal Dimensions | 20 × 10 × 50 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Package Contents | 1 × Quartz sample cell |
| Fabrication Method | Molded 83 |
| Opening Configuration | Open at Both Ends |
| Pack Quantity | 1 Piece |
Choose this option
Choose MQQFC021 when you want both 20 mm and 10 mm transmission paths available in the same rectangular quartz cell body. It is especially suitable for fixture-based setups where you need a larger chamber and side-to-side optical access, but prefer to define the end support, filling and sealing method yourself rather than use a preassembled flow-cell connection.
View the English selection reference. Also available in the product gallery. Group photographs illustrate other options in the series.
What makes this option different
- 20 mm and 10 mm optical paths in one cell: useful when one method or workflow needs two defined transmission directions without changing the sample chamber.
- Four-Way Light layout: provides optical access through two opposing face pairs, which matters when the measurement orientation is part of the method design.
- Open at both ends: lets you build the filling, support and sealing arrangement around the cell body.
- 10 mL nominal capacity: suited to applications that need a larger chamber than compact micro cells.
- Molded 83 fabrication: this construction is commonly selected for organic-solvent methods, while full suitability still depends on the complete wetted assembly you use with the open ends.
- ±0.02 mm path tolerance: specified for the listed path lengths as a grade tolerance target.
Structure and dimensions

Using this cell
Align the cell to the path length required by your procedure and keep that orientation consistent for blank and sample measurements. If you use both optical directions in the same workflow, mark the orientation clearly in the holder or SOP so the 20 mm and 10 mm paths are not mixed during handling.
The stated 10 mL is the nominal chamber capacity, not a minimum working volume. Because the body is open at both ends, the practical filled assembly will depend on the seals or other end parts used in your own setup.
First-use check
- Inspect the optical faces, end edges and chamber opening before installation.
- Test the cell in the intended holder and confirm which orientation corresponds to each path length.
- Run a blank after filling and remove bubbles or exterior droplets before recording measurements.
Fit and optical alignment
Check holder clearance against the 26 × 16 × 50 mm external dimensions of the uncapped cell body. The internal 20 × 10 × 50 mm dimensions describe the sample region and should not be used as outside fit dimensions.
Z Height is not listed for this SKU. If your instrument or fixture depends on a fixed beam-center height, confirm the alignment in your actual holder before ordering.

Solvents and cleaning
This cell uses Molded 83 fabrication, based here on the supplier’s optical-contact construction. It is commonly chosen for organic-solvent methods, but compatibility still depends on the full wetted setup, including any seals, fittings or other parts added to the open-ended body.
Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaning methods. Clean the optical faces gently with non-abrasive lab tissue.
Included with this option
1 quartz sample cell. The listed price is for one piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
If you need a different path length, outer size, opening arrangement, window layout or tolerance target, please send your drawing or holder details through the contact page. Custom JGS1 quartz projects are reviewed separately from the listed SKU, with feasibility, quantity, price and production time confirmed case by case.
Additional information
| Weight | 150 g |
|---|
You must be logged in to post a review.











Reviews
There are no reviews yet.