(C104SR14) Quartz Micro Cuvette, 10 mm Path, 1.75 mL
Original price was: $293.00.$264.00Current price is: $264.00.
C104SR14 is a JGS1 quartz micro cuvette for fluorescence spectroscopy with a 10 mm optical path, Four-Way Light access and a 1.75 mL nominal capacity. Its 5 mm sample-region width gives the widest defined measurement zone among these related micro formats while keeping the same 12.5 × 12.5 mm body footprint. Sold as 1 cuvette, with a closure included.
Description
C104SR14 is a quartz micro cuvette for fluorescence spectroscopy when you need a 10 mm optical path together with multi-side optical access and a broader sample region. This JGS1 quartz option combines Four-Way Light geometry, a 5 mm sample-region width and a 1.75 mL nominal capacity in a compact 12.5 × 12.5 mm body, with a closure included for covered sample handling.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 1.75 mL
- Closure Type
- Stopper
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | Fluorescence Spectroscopy |
| Pack Quantity | 1 Piece |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Optical Window Dimensions | 5 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 1.75 mL |
| External Dimensions | 12.5 × 12.5 × 45 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Closure Type | Stopper |
| Closure Included | Yes |
| Detection Channel Width | 5 mm |
Choose this option
Choose C104SR14 when your setup uses a 10 mm path length and you want a broader defined sample section within the same compact external format. The 5 mm sample region is useful when beam placement and sample coverage matter, and the Four-Way Light layout suits fluorescence arrangements that use optical access from multiple faces rather than a simple two-window transmission path.
What makes this option different
- 10 mm optical path for methods built around that standard length.
- Four-Way Light geometry for optical access from multiple sides.
- 5 mm sample-region width for a broader defined illuminated section.
- 1.75 mL nominal capacity in a 12.5 × 12.5 mm footprint, with a closure included.
Using this cell
Load the sample so the beam passes fully through liquid in the intended measurement region, and keep the optical faces clean and free from bubbles, droplets and dried residue. For repeatable work, keep the same orientation in the holder for blank and sample runs.
The 1.75 mL value is the nominal capacity of the cuvette, not a minimum working volume. If your method uses a lower fill level, check that the illuminated region remains fully covered in your own instrument geometry.
First-use check
- Inspect the cuvette for clean, undamaged optical faces and edges.
- Rinse with a suitable liquid for your method and dry the exterior optical faces carefully.
- Place the cuvette in the holder and confirm correct seating and beam position.
- Run a blank before routine measurements, especially when alignment is important.
Fit and optical alignment
The stated external dimensions are 12.5 × 12.5 × 45 mm, with a 12.5 × 12.5 mm base. This compact footprint is useful when you need a micro cuvette body but still want a broader sample region and covered top access.
The 5 mm figure describes the sample-region width, not an instrument slit size. Z Height is not specified for this option, so if your fluorimeter or holder depends on a known beam-center height, please confirm that requirement before purchase.
Solvents and cleaning
Quartz supports work across the stated 200–2500 nm range. Clean the exterior optical faces gently with non-abrasive optical tissue or laboratory wipes, and avoid abrasive powders or scraping.
The chemical limits for this exact assembly are not established here. If your sample or cleaning routine involves aggressive chemicals, elevated temperatures or long contact times, please check suitability before use. Do not use hydrofluoric acid on quartz, and avoid hot strong alkalis. For general fabrication background, see MQ Cuvette Fabrication Glossary.
Included with this option
One C104SR14 micro cuvette. A closure is included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz cuvettes for changes involving dimensions, path length, sample volume, optical windows, Z Height, closures and tolerances. Send a dimensioned drawing or labelled sketch together with your holder details, wavelength range, sample conditions and target quantity. Contact us here and quote C104SR14.
Additional information
| Weight | 30 g |
|---|
You must be logged in to post a review.