(C102SE5) Quartz Micro Cuvette, 10 mm Path, 1.05 mL
Original price was: $143.00.$129.00Current price is: $129.00.
C102SE5 is a quartz micro cuvette for UV/Vis spectroscopy with a 10 mm optical path, Two-Way Light layout and 1.05 mL nominal capacity. This version includes a stopper and a 3 mm sample-region channel width, making it useful when you want a covered micro-cell format for routine handling. Sold as 1 cuvette per price unit.
Description
C102SE5 is a quartz micro cuvette for UV/Vis work with a 10 mm optical path, Two-Way Light configuration and 1.05 mL nominal capacity. The included stopper gives you a covered sample cell, and the 3 mm sample-region channel width is useful when you need a narrow sample region rather than a larger standard cell interior. Quartz construction supports use across the stated 200 to 2500 nm range.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 1.05 mL
- Closure Type
- Stopper
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Micro Cuvette |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Two-Way Light |
| Optical Window Dimensions | 3 mm |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 1.05 mL |
| Material | Quartz |
| Closure Type | Stopper |
| Closure Included | Yes |
| Detection Channel Width | 3 mm |
Choose this option
Choose C102SE5 when your method uses a 10 mm path length but you prefer a micro cuvette with a stopper instead of an open-top filling format. The covered opening is helpful for routine handling, and this option is presented for volatile-solution use. Its 1.05 mL nominal capacity and narrow 3 mm sample region make it a practical choice when your setup calls for a compact UV/Vis cell body with a defined illuminated zone.
What makes this option different
- 10 mm optical path in a quartz micro cuvette format for UV/Vis spectroscopy.
- Stopper closure is included, so the cell is supplied as a covered sample-cell configuration.
- 1.05 mL nominal capacity provides a compact cell format without moving up to a larger standard cuvette body.
- 3 mm sample-region channel width is a useful geometry detail when planning beam coverage and fill practice.
Using this cell
Fill the cuvette so the illuminated region is completely covered during measurement, and check that no bubbles or droplets remain across the optical faces. Insert the stopper gently after filling, and keep the same orientation for blank and sample measurements if your method depends on consistent positioning.
The nominal capacity describes the cell format, not the minimum working volume. Before routine use, establish a fill level in your own instrument that keeps the beam path fully in liquid and clear of the meniscus.
First-use check
- Inspect the optical faces under good light and rinse before first use.
- Place the empty cuvette in the holder to confirm it seats without force.
- Run a blank first and confirm the beam passes cleanly through the filled sample region.
- Check that the stopper sits properly before starting your sample series.
Fit and optical alignment
This cuvette has a narrow sample-region channel width, so beam position matters more than it would in a broader chamber. The 3 mm figure refers to the sample-region channel width, not to an instrument slit setting.
Check holder fit and beam height if your instrument uses a fixed beam position or a dedicated micro-cell adapter. Z Height is not established here, so instrument fit should be checked from the holder and beam geometry rather than assumed from the 10 mm path length alone.
Solvents and cleaning
This quartz cuvette is specified for UV/Vis use, but the chemical limits of this stopper-equipped assembly are not established here. If your sample or cleaning routine involves aggressive solvents or long contact times, review those conditions before use. Compare fabrication options if you are selecting for a particular chemical routine.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning methods, and clean the optical faces with non-abrasive lab tissue or another suitable gentle wipe.
Included with this option
1 cuvette per listed price unit. Closure included.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We coordinate custom JGS1 quartz production for requirements involving dimensions, optical path length, sample volume, optical windows or Z Height, closures and connections, fabrication and tolerances. Send a dimensioned drawing or labelled sketch and identify the dimensions and tolerances that are critical to your application. Prototype batches typically involve 2–4 cells; final feasibility, specifications, quantity, price and production time are confirmed in the quotation. Discuss your requirements and quote part number C102SE5.
Additional information
| Weight | 30 g |
|---|