(C204CS1) Quartz Rectangular Sample Cell, 20 mm / 50 mm (dual path) Path, 60 mL
Original price was: $357.00.$322.00Current price is: $322.00.
JGS1 quartz rectangular sample cell with a 20 mm / 50 mm dual optical path, Four-Way Light access and an open-top chamber for direct filling. Its 60 mL nominal capacity suits fluorescence work that uses a larger sample volume and benefits from optical access on all four vertical faces. Sold as 1 cuvette per listed price unit.
Description
C204CS1 is a JGS1 quartz rectangular sample cell for fluorescence measurements that need a larger open chamber and a defined dual optical layout. This option combines a 20 mm path with a 50 mm secondary path, Four-Way Light access and a 60 mL nominal capacity, so you can work with a larger sample body while keeping direct top access for filling and rinsing.
- Path Length
- 20 mm / 50 mm (dual path)
- Sample Volume (Nominal)
- 60 mL
- Opening Configuration
- Open Top
Selection Specifications
| Product Kind | Cuvette |
|---|---|
| Cell Type | Rectangular Sample Cell |
| Measurement Mode | Fluorescence Spectroscopy |
| Path Length | 20 mm / 50 mm (dual path) |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 60 mL |
| External Dimensions | 54 × 24 × 70 mm |
| Cell Body Dimensions | 54 × 24 × 70 mm |
| External Dimensions Scope | Body Only |
| Internal Dimensions | 50 × 20 × 68 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Opening Configuration | Open Top |
Choose this option
Choose C204CS1 when your setup needs a rectangular fluorescence cell with direct access from the top and optical access from four sides. The dual 20 mm / 50 mm path arrangement is useful when your method depends on specific light directions through the same body, and the larger chamber size helps when a small cuvette volume is not suitable for the way your sample is prepared or handled.
What makes this option different
- Dual path body: one cell provides 20 mm and 50 mm path directions for methods built around a defined orientation.
- Four-Way Light configuration: all four vertical faces are available for optical access in fluorescence-style layouts.
- Open-top chamber: fill, empty and rinse directly from above instead of working through tubing or a fixed closure.
- Large nominal capacity: the listed chamber capacity is 60 mL for applications that use more sample than a standard small cell body.
Using this cell
Fill the cell from the open top and keep the liquid level high enough to cover the beam region used by your instrument. Remove bubbles from the optical region before measurement, and keep the same orientation for blank and sample runs if your method depends on a specific path direction.
The open chamber is practical when you need direct access for pipetting, pouring, emptying or rinsing between runs. No minimum working volume is established here, so final fill level should be set from your actual beam position and measurement geometry rather than from nominal capacity alone.
First-use check
Inspect the four optical faces and the open chamber for dust, chips or residue before use. After rinsing with a suitable liquid for your method, run a blank and confirm that the filled sample covers the beam region without visible bubbles on the optical faces.
Fit and optical alignment
The stated 54 × 24 × 70 mm dimensions apply to the cell body only. Use them to check holder clearance and surrounding space for a taller rectangular cell, but do not treat the body size alone as proof of instrument compatibility.
The internal dimensions are 50 × 20 × 68 mm, which help you judge chamber size and sample access. Z Height is not specified for this option, so fixed-beam instruments should be checked against your holder or fluorimeter geometry before ordering.
Solvents and cleaning
This cell body is quartz in JGS1 grade. Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning materials, and wipe the exterior optical faces gently with non-abrasive optical tissue.
Exact chemical limits are not established for this specific configuration, so aggressive reagents and dedicated cleaning routines should be checked against your full sample conditions before use. For general background on MQ fabrication categories, see Compare fabrication methods.
Included with this option
1 cuvette per listed price unit. If you need a supplied closure or other accessory, contact us before ordering.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review custom JGS1 quartz versions based on dimensions, optical path length, sample volume, optical windows, Z Height, openings and fabrication requirements. Send a dimensioned drawing or labelled sketch together with holder details, wavelength range, sample conditions and target quantity at https://machinedquartz.com/contact/, and reference part number C204CS1.
Additional information
| Weight | 100 g |
|---|
You must be logged in to post a review.






Reviews
There are no reviews yet.