Site Navigation

(MQQFC010) Quartz Rectangular Sample Cell, 2.5 mm Path, 3 mL, Open at Both Ends

Weight50 g
SKU: MQQFC010

$179.00

In Stock

MQQFC010 is a JGS1 quartz rectangular sample cell with a 2.5 mm optical path, Two-Way Light geometry and 3 mL nominal capacity for UV/Vis work from 200 to 2500 nm. Its open-at-both-ends body leaves the end interface to your holder or sealing arrangement rather than providing fixed ports or caps. Sold as 1 piece.

In Stock
Add to Wishlist
Add to Wishlist
Shipping and order support
  • Worldwide delivery to door service, hassle free shipping
  • Contact us for quotation of bulk purchase discount
  • Custom design. Send us graphic drawing for solution
  • POs for Academics. Pay after delivery.
  • Availability and dispatch timing vary by item and quantity. Contact us to confirm timing for your order.

Description

MQQFC010 is a JGS1 quartz rectangular sample cell for UV/Vis measurements from 200 to 2500 nm. It combines a 2.5 mm optical path with a 3 mL nominal chamber in an open-at-both-ends body, which is useful when the sample region and the space around the cell need to be planned together with your fixture. This format suits transmission setups where you want to define how the ends are supported, filled or sealed in your own assembly.

Path Length
2.5 mm
Sample Volume (Nominal)
3 mL
Opening Configuration
Open at Both Ends

Selection Specifications

Product KindSpecialized Cell
Cell TypeRectangular Sample Cell
Measurement ModeTransmission Spectroscopy
Path Length2.5 mm
Light Transmission ConfigurationTwo-Way Light
Wavelength Range — Lower Limit200 nm
Wavelength Range — Upper Limit2500 nm
Sample Volume (Nominal)3 mL
External Dimensions40.5 × 11.5 × 40.5 mm
Body Height40.5 mm
Base Dimensions40.5 × 11.5 mm
Internal Dimensions32 × 2.5 × 40.5 mm
MaterialQuartz
Material GradeJGS1
Fabrication MethodStandard 80
Opening ConfigurationOpen at Both Ends
Pack Quantity1 Piece

Choose this option

Choose this cell when you need a 2.5 mm transmission path in a rectangular chamber and want direct access from both ends. The open-ended format gives you more freedom to build the surrounding holder or end arrangement for your process, while the 32 × 2.5 × 40.5 mm internal chamber and 3 mL nominal capacity help you judge whether the sample region fits your method and handling approach.

View the English selection reference. Also available in the product gallery. Group photographs illustrate other options in the series.

What makes this option different

  • Open at both ends: you can access the chamber from either end when planning filling, support or a separate sealing arrangement.
  • 2.5 mm optical path: suited to methods built around this transmission distance without moving to a longer path body.
  • Two-Way Light layout: intended for through-beam transmission across the defined optical path.
  • 3 mL nominal capacity: gives a larger sample chamber than micro-volume formats while remaining within a compact rectangular body.
  • 32 × 2.5 × 40.5 mm internal chamber: useful when the chamber length and access geometry matter for filling direction or fixture design.
  • Standard 80 adhesive-bonded construction: a practical choice for routine room-temperature aqueous samples and buffers, with more care needed in solvent selection and cleaning.

Structure and dimensions

Product dimensions for checking holder clearance and sample access.
Product dimensions for checking holder clearance and sample access.Open image ↗

Using this cell

Mount the cell so the beam passes through the 2.5 mm path across the transmitting faces. Because the body is open at both ends, decide first how the sample will be introduced and retained in your fixture, especially if the cell will be used with seals, adapters or other supporting parts.

The 3 mL figure is the nominal chamber capacity of the cell body itself. It should not be treated as a minimum working fill or as the total liquid volume of a complete assembly once end fittings, seals or connected tubing are added.

First-use check

  1. Inspect the optical faces, end openings and body edges for chips, residue or handling damage.
  2. Test the fit in your holder before routine use, including the space needed at both ends for filling or sealing.
  3. Verify that the beam crosses the intended window area without obstruction from clamps, supports or adapters.

Fit and optical alignment

Use the 40.5 × 11.5 × 40.5 mm external dimensions to check holder clearance, support area and end access around the body. This cell is a rectangular sample body, not a ready-to-connect flow assembly, so the installed fit depends on the holder or sealing parts you use with it.

Z Height is not specified for this SKU. If your instrument or fixture requires a defined beam-center height, check that geometry before ordering or send the mounting details for review.

English selection reference
Selection reference ↗

Solvents and cleaning

This cell is listed as Standard 80, using an adhesive-bonded quartz construction. It is typically selected for routine room-temperature aqueous samples and buffers. Avoid organic samples and organic cleaning solvents on the bonded assembly; if your method involves organic solvents or heating, ask about a more suitable sintered or molded alternative.

Keep hydrofluoric acid away from quartz. Avoid hot strong alkalis and abrasive cleaners, and clean the optical faces gently with non-abrasive lab wipes.

Included with this option

1 rectangular sample cell. The listed price is for one piece. Any closure, holder or other accessory should be checked with your ordering requirement.

Availability and ordering

Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.

Discuss a custom version

We coordinate custom JGS1 quartz production for projects involving path length, chamber dimensions, external envelope, opening details and fabrication requirements. If your setup depends on a specific beam height, holder fit or end interface, send a dimensioned drawing or labelled sketch with the critical dimensions and tolerances.

Send a product-selection enquiry with SKU MQQFC010, your holder or interface details, sample conditions, quantity and delivery destination.

Additional information

Weight50 g

Reviews

There are no reviews yet.

Be the first to review “(MQQFC010) Quartz Rectangular Sample Cell, 2.5 mm Path, 3 mL, Open at Both Ends”

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare