(MQQFC098) Molded 83 Quartz Flow Cell, 10 mm Path, 3.5 mL, Detachable PTFE Fittings
$551.00
JGS1 quartz flow cell with a 10 mm optical path, 3.5 mL nominal capacity and Molded 83 fabrication. Opposed detachable PTFE fittings provide 5 mm OD / 2 mm ID tube stubs, while four optical side faces leave access around the sample chamber. The 45 mm quartz body forms part of a 79 mm assembled span; one cell supplied.
Description
MQQFC098 is a JGS1 quartz flow cell for UV/Vis setups that need a 10 mm flow-through optical path in a larger chamber format. Its 3.5 mL nominal capacity, four-sided optical access layout and opposed detachable PTFE fittings make it useful when you want a straight end-to-end liquid route while keeping side optical access around the sample region.
- Path Length
- 10 mm
- Sample Volume (Nominal)
- 3.5 mL
- Opening Configuration
- Two Opposed Detachable Fluid Fittings
Selection Specifications
| Product Kind | Flow Cell |
|---|---|
| Cell Type | Flow Cell |
| Measurement Mode | UV/Vis Spectroscopy |
| Path Length | 10 mm |
| Light Transmission Configuration | Four-Way Light |
| Wavelength Range — Lower Limit | 200 nm |
| Wavelength Range — Upper Limit | 2500 nm |
| Sample Volume (Nominal) | 3.5 mL |
| External Dimensions | 79 × 12.5 × 12.5 mm |
| Cell Body Dimensions | 45 × 12.5 × 12.5 mm |
| External Dimensions Scope | Installed Assembly |
| Body Height | 45 mm |
| Base Dimensions | 12.5 × 12.5 mm |
| Internal Dimensions | 10 × 10 × 37 mm |
| Material | Quartz |
| Material Grade | JGS1 |
| Port Count | 2 |
| Tube Outer Diameter (OD) | 5 mm |
| Tube Inner Diameter (ID) | 2 mm |
| Fabrication Method | Molded 83 |
| Opening Configuration | Two Opposed Detachable Fluid Fittings |
| Fitting Material | PTFE |
| Detachable Fittings | Yes |
| Port Layout | Opposed end A, shown on the left of the exact original; Opposed end B, shown on the right of the exact original |
| Pack Quantity | 1 Piece |
| Package Contents | 1 × Quartz Flow Cell |
Choose this option
Choose this cell when you need a flow cell rather than a hand-filled cuvette, and when a 10 mm path is required together with a comparatively large internal chamber. The 10 × 10 × 37 mm chamber gives you a defined sample region inside the optical body, while the two opposed fittings suit layouts where tubing approaches from the two ends instead of from the top.
What makes this option different
- 10 mm optical path in a flow-through quartz body for UV/Vis measurements.
- 3.5 mL nominal capacity with a 10 × 10 × 37 mm internal chamber.
- four-sided optical access configuration for optical access from more than one pair of sides.
- Opposed detachable PTFE fittings with 5 mm OD / 2 mm ID tube stubs.
Using this cell
The 5 mm outer diameter and 2 mm inner diameter describe the PTFE tube stubs on the cell. Select mating tubing by its fit over those stubs and by the tubing manufacturer’s recommendations; these numbers are not a specified size for a separate hose. The detachable parts are the fluid fittings, not a split optical sample chamber.
Install the cell so the optical faces stay clean and the end fittings are not carrying the weight of the connected tubing. Fill the chamber gradually and inspect the optical region before measurement so trapped bubbles do not remain in the light path.
The 3.5 mL figure is the nominal capacity of the cell itself, not the total liquid volume of the full flow circuit. The two end connections identify the physical layout only; they do not assign inlet and outlet roles, so flow direction should follow your own system design.
First-use check
- Inspect the optical faces, chamber and fittings before installation.
- Seat the cell in the holder and verify that the beam crosses the intended optical region.
- After filling, remove visible bubbles and repeat the blank in the installed position.
Fit and optical alignment
View the English selection reference.
The assembled size is 79 × 12.5 × 12.5 mm. Within that assembly, the optical body length is 45 mm, with a 12.5 × 12.5 mm section and a 10 × 10 × 37 mm internal chamber. This distinction matters if your holder grips the body while the tubing and fittings extend beyond it.
Z Height is not established for this SKU, so holder fit should not be judged from the outer size alone. Leave extra space beyond the 79 mm assembly for tubing approach, bend radius and access to the detachable fittings.

Solvents and cleaning
This cell uses Molded 83 quartz construction. This fabrication is commonly chosen for organic-solvent methods and applications that may involve temperature, but the practical limit depends on the complete wetted assembly, including the detachable PTFE fittings.
Do not use hydrofluoric acid on quartz. Avoid hot strong alkalis and abrasive cleaning. For aggressive liquids, elevated temperature or long contact time, check suitability for the full assembly before use.
Included with this option
1 Quartz Flow Cell. The listed price is for 1 piece.
Availability and ordering
Order this specification directly, or contact us to check current availability and dispatch timing. If temporarily unavailable, additional preparation or production time may be needed. For a required delivery date, contact us before checkout; preparation or production is separate from carrier transit and customs clearance.
Discuss a custom version
We can review custom JGS1 quartz versions for changes to dimensions, optical path length, sample volume, optical layout, connections and related tolerances. Send a dimensioned drawing or labelled sketch, together with holder details, liquid conditions and required quantity. Send a product-selection enquiry with SKU MQQFC098.
Design notes for this configuration: Quartz Flow Cell with Removable PTFE Fittings: Planning Connection Maintenance
Additional information
| Weight | 50 g |
|---|
You must be logged in to post a review.









Reviews
There are no reviews yet.